Jm 103 Jaundice Meter Manual

  



A simple, effective, portable non-invasive jaundice meter

The transcutaneous jaundice meter from Delta Medical International offers a reliable, non-invasive method for screening babies for jaundice. The product is convenient, effective and proven, reducing the need for blood sampling and thus contributing to developmental care practice.

Jaundice meter jm - 103 service manual Jaundice Meter Jm-103 Service Manual from Rambeau Christophe is another addition to the growing number of free media players out there. As media players go, Jm103 service manual - complete pdf download draeger JM 103 Created Date: Drager JM-103 User Manual. Refer to the appropriate. Jaundice Meter (Model JM-103) User Manual (usr070rb) Page 4 - 1. SAS/STAT 15.1 User’s Guide The presence of bilirubin or urobilinogen in the urine may indicate abnormally increased breakdown of red blood cells, liver disease or a blockage of bile flow into the intestines. Manuals and User Guides for Konica Minolta JM-103. We have 1 Konica Minolta JM-103 manual available for free PDF download: User Manual Konica Minolta JM-103 User Manual (76 pages). Staff responsible for using the Jaundice Meter JM-105 will receive a demonstration of the JM-105 by an experienced Jaundice Meter JM-105 operator OR will view the Jaundice Meter JM-105 training video. Learners are also responsible for reading the information provided in the Operating Instructions Manual. Page 2 - 2 Jaundice Meter Instructions for Use (MU01380) Phototherapy WARNING: Do not use the Jaundice Meter after initiation of phototherapy or after an exchange transfusion. Results may be inaccurate under these conditions. Explanation of the Test Measuring Principle The Jaundice Meter determines the yellowness of an infant’s.

Clinical Background

Jm 103 Jaundice Meter Manual

Neonatal jaundice occurs frequently in newborn babies1 and has long been a concern for healthcare professionals. If left untreated it can have severe consequences for the child, so early detection is vital.

The use of visual inspection alone is widely considered unacceptable as it can lead to false estimates2, with babies then being put at risk of hyperbilirubinemia due to under-estimation. Equally visual examination may also lead to over-estimation of babies at risk, resulting in unnecessary invasive blood testing of total serum bilirubin (TsB).

It is recognised that the bilirubin levels of newborn infants often peak two to four days after delivery, after most term babies have gone home3 and can lead to them needing to be readmitted to hospital for treatment. Screening using a non-invasive measurement can thus offer a simple and convenient way to avoid later complications.

Once diagnosed jaundice can often be simply treated by using a phototherapy system to break down excess bilirubin levels.

Transcutaneous Bilirubin Measurement

It is well established that the transcutaneous measurement of bilirubin level is well correlated with serum concentration2,3,4. The advantages to the healthcare professional and the patient of being able to determine bilirubin levels instantly and non-invasively are obvious.

Portable transcutaneous jaundice meters offer a quick and easy method for dynamic and ongoing assessment to identify abnormal bilirubin levels. They are suitable for use in all clinical settings: NICU; SCBU; maternity; post-natal; and in the community.

Developmental Care Considerations

It is well documented that neonates undergo numerous invasive procedures on a daily basis5; this not only causes unnecessary stress on the infant, but can also impact their long-term developmental care outcome. Using a transcutaneous jaundice meter dramatically reduces the need to take blood samples for hyperbilirubinemia testing; no painful needles is much kinder to babies.

The simplicity of operation and speed of obtaining readings with the jaundice meter that Delta Medical supply makes repeated testing to measure efficacy of treatment possible, with minimal impact on the patient. It is therefore practical to determine whether further intervention needs to be considered and to optimise patient care whilst following best developmental care principles. The reduction in neonatal stress and parental anxiety add to the process of optimising developmental care.

Product Features & Benefits

MBJ20 jaundice meter is very simple to apply and operate, making it very quick and easy to obtain bilirubin readings with minimal disturbance to the baby. The compact ergonomic design makes it easy to hold, with a display that is easy to read, and very convenient to carry around. It is suitable for screening infants from 35 weeks’ gestation and automatically stores the last 20 readings for review if needed.

The advanced optical design and processing algorithms ensure highest accuracy. Self-calibration ensures accuracy and efficacy; the unit is supplied with an external calibration unit for periodic checks and adjustment; there is negligible maintenance required.

The unit is easily cleaned for infection control. The reduction in need for blood sampling gives further potential advantages in relation to infection prevention in addition to the developmental care considerations.

The portability and simplicity make the unit ideal for use in all areas, including routine post-natal care and community care. The jaundice meter can facilitate routine screening and accelerate appropriate care and treatment of babies who may have an elevated bilirubin level.

Product Specifications

References

  1. National Institute for Health & Care Excellence (NICE). Clinical Guidance CG98: Jaundice in newborn babies under 28 days. www.nice.org.uk, 2010
  2. American Academy of Pediatrics Subcommittee of hyperbilirubinemia. Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation. Pediatrics, 2004
  3. Holland, L., & Blick, K. Implementing and validating transcutaneous bilirubinometry for neonates. AJCP, 2009.
  4. Najundaswamy, S, Petrova, A., et al. The accuracy of transcutaneous bilirubin measurements in neonates: a correlation study. Neonate, 2004
  5. Carbajal, R., Rousset, A., Danan, C., et al. Epidemiology and treatment of painful procedures in neonates in intensive care units. JAMA, 2008

Brochure Download

Click to download the Jaundice Meter product brochure

One moment please...
Not A Member?Sign Up
0 Replies

Is this a point of care device? Is this a waived test?

RE: Draeger - JM-1037 Replies

Is there a calibration for this JM-103 if the tests are outside of the stated values with their tolerances?

RE: Draeger - JM-103Jm 103 Jaundice Meter Manual1 Reply

Need manual to learn how to test jaundice meter for accuracy, specifically the parameters as I know how to perform the test.

RE: Draeger - JM-1032 Replies

Our Bili meter all of a suddent changed units of measure and is inaccurate. Can you help me problem solve?

RE: Draeger - JM-1030 Replies

I just want to ask if we can replace the rechargeable battery? It keeps on blinking and we hardly see the numbers although it's charged properly.Thanks

RE: Draeger - JM-103

Jm 103 Jaundice Meter Manual Pdf

0 Replies

I am looking for a company to calibrate our Drager JM-103 Jaundice Meter. PLease notify me with a company that will do this calibration. Thank you

Jm 103 Jaundice Meter Manual 1

RE: Draeger - JM-1031 Reply

AVAILABILITY SIZE NUMBER INFO??

Jm-103 Jaundice Meter Service Manual

RE: Draeger - JM-1030 Replies

within which range is the jm 103 reliable, i.e. lab tests from blood specimens and meter readings are comparable? some iof the meters have increasing differences in higher ranges...

can the jm 103 be used for premature babies, if so from what prgnancy week /birth weight?

RE: Draeger - JM-103Jaundice0 Replies

Is this instrument subject to CLIA regulations?

ManualRE: Draeger - JM-1030 Replies

Looking for calibration procedure for this Jaundice meter. the staff says it is reading high. I have cleaned the sensors. Thank you in advance, Bert

RE: Draeger - JM-103